Measurements on partial discharge in on‐site operating power transformer: a case study
2018
This study presents the case study of a substation in-service power transformer referred to the on-site partial discharge (PD) detection and evaluation methods. An original methodology for simultaneous application of three methods is proposed: electrical, acoustic and ultra-high frequency. Transformer is powered by the power grid and no external generator is required according to the proposed methodology. Furthermore, several possibilities of applying these concurrent measurements and benefits of such solution in terms of result interpretation, interference resistance and on-site measurement applicability are indicated. The proposed methodology allows for a fast, accurate and secure PD diag…
A New Approach to Partial Discharge Detection Under DC Voltage: Application to Different Materials
2021
Usability of a new Direct Current Periodic waveform for partial discharge qualification in HVDC systems is exemplified by tests performed on different materials.
Partial discharges behavior under different rectified waveforms
2017
In this work, a previous software used to simulate partial discharges (PDs) under Alternating Current (AC) stress has been modified in order to evaluate the PDs behavior under a voltage stress close to the Direct Current (DC) waveform. By using a full-wave and a half-wave rectifier, the specimen with an air void defects has been subjected to a gradual constant stress. Finally, a capacitive filter has been inserted in order to produce a steadier voltage supply. Simulation results show that under an almost DC waveform, the PDs activity become less compared to AC stress.
PD characteristics at Square Shaped Voltages Applying Two Different Detecting Techniques
2016
Nowadays power electronic converters are widely used and the fast switching voltage fronts results in an increased stress on the insulation material and may cause a reduction of the HV systems reliability. Nonsinusoidal voltage waveform have influence on the partial discharges (PD) characteristics in insulating systems due to the increased harmonic content which causes problems mainly in electrical PD measurement setups. In fact, impulse voltages cause strong switching disturbances, which make it much more difficult to distinguish PD signals from noise. This work investigates the influence of repetitive steep pulses on different types of test objects exposed to square wave voltages applying…
Partial discharges at different voltage waveshapes: Comparison between two different acquisition systems
2018
In modern HV apparatuses the wide use of electronic converters, increase the stress on the involved insulation systems and thus affect the reliability of the whole power grid. Additionally, such non-sinusoidal voltage shapes contain high gradient flanks that create problems in the detection of partial discharge (PD) activity. The aim of this paper is to discuss the methodology on how to suitably approach PD detection in insulation systems exposed to various voltage waveshapes in general by comparing two different measuring systems. The first one, equipped with a resonant PD decoupler, designed specifically for detection at typical power electronic waveshapes and the other one, based on an a…
Space Charges and Partial Discharges Simultaneous Measurements under DC Stress
2016
In the field of HVDC, the main causes of insulation aging are due to the space charge and PD phenomena. In particular, the purpose of the present work is to verify a possibility to measure simultaneously the space charge and the PDs under DC stress in order to evaluate the correlation between both phenomena. The space charge was measured by using a modified PEA cell and PDs were measured by using a novel wireless sensor system. The space charge profile and the PD pulses carried out simultaneously have been reported and discussed.
Partial discharge of gel insulated high voltage power modules subjected to unconventional voltage waveforms
2016
Performances and duration of the new generation of high voltage power electronic components are dependent on dielectric materials aim to insulating their internal terminals. The presence of defects, some due to faults generated during the manufacturing process, but also due to the internal design of layers and connections, can cause local enhancements of electric field and consequently possible activity of partial discharges phenomena or other effects (aging, tracking) that may result in reduction of device reliability. Furthermore, the usage of unconventional voltage waveforms, like square waves or pulse width modulated waves, additionally increases the electrical aging of the insulation s…
Partial discharge detection and localization along medium voltage cables
2017
In the last years different partial discharge (PD) measuring techniques have been developed because PD diagnostic is the most widely tool to evaluate the insulation condition of a power cable. Recently non-conventional methods and sensors have been used in order to reach improved results in PD measurements. The purpose of this work is to perform measurements that allow to study the variation of pulses when they travel along a MV cable and to locate the pulse source through the time arrival difference of the pulses obtained from two sensors installed separately.
Deformation of bubbles in silicon gel insulation under an alternating electric field
2019
The behavior of silicone gel under electrical stress plays a significant role in the reliability and durability of high voltage electronic power devices due to its widespread use for the insulation of IGBT modules and other components. The charges accumulation at the bubble boundaries leads to significant displacements due to the establishment of Coulombic forces and the high deformability of colloidal system. The main purpose of this work is to validate a numerical approach useful to investigate, for a given silicone gel, the non-linear relation between the applied HVDC stress and the electric field over an air bubble within the insulation bulk. The analysis has been carried out by means o…
Critical issues in the PD testing methodology for XLPE-insulated MV cables: An experimental case
2017
This paper describes some critical issues arising during the partial discharge (PD) testing of a 500m delivery length of an XLPE-insulated MV cable. At first, conventional PD measurements were performed on the whole length by using a standard acquisition system; PDs activity was detected, but the system allowed the operator to localize the PDs only on a length of 70 m. A visual inspection of this section highlighted the presence of an excoriation in the outer sheet. Aiming at a more accurate pin-pointing of the defect, more measurements were carried out in the proximity of the outer defect using a portable PD detection system. These measurements showed PDs activity, whose source was located…